Why are quick closing valve fitted in a fuel system?

Quick closing valve are fitted in the fuel system so that in the event of a fire in the vicinity of these systems or break in these lines the system can be shut down rapidly and remotely, these valves are pneumatically operated. If by any means control air fails to reach the valve the system will fail.