Skip to main content

Posts

Showing posts with the label MEO Class 4 Oral Questions

MEO Class 4

Safety: Solas New Reg. For bulk carrier Docking plug 10 yr maintenance in co2 bottle ad how to pressure test in shore SOx ad NOx reduction Fire wallet ASDU Medical assistance publication name Fixed foam Solas regulations Smoke signal chemical composition Mob marker regulation Iopp renewal survey details Foam system solas regulation, fire hydrant, foam monitor, also educator and proposnator difference.  Port state and flag state difference SOPEP regulation & duties  SBT and clean ballast difference. ORB both Motor: manual purifier desludge and check during desludge bilge pump priming and bilge line leakage detection drill bit order A/E performance parameters checks fuel duplex filter change over specific lube oil consumption COPT safety M/E specifications and which type MEP: Fuel injector overhaul FWG not maintaining vacuum Scavenge space inspection MAC trips How to order flange AE Unit no. 1 exhaust temp high Change over process ...

MEO Class 4

Safety: IMO structure and purpose Coffin plate, permeability SOPEP Fixed fire fighting system CO2 Portable fire extinguisher Fire in electric  board what actions to take Marpol annex 5 Disposal criteria of synthetic mooring ropes, Can it be disposed into the sea Fresh water allowance Where is it shown on your ship FW allowance & show the length  in diagram  from where to where Bulk carrier midship section diagram Stern frame  diagram Plimsolls diagram. Free surface effect?, Good or bad , how to reduce by operation. Collection bulkhead?purpose arrangement  Corrugated bulkhead? purpose, arrangement  Eng. Bilge line connection, how to check valve good in operation, type of emg bilge valve. What Equipment/ system u will check in FSA , what inspection u carried out on fire hose, fire hydrant , nozzles. Portable fire extinguisher check list. Engine room fire different cause. Annex 4, discharge criteria. Motor: Engine type st...

MEO Class 4

Safety: What all Portable fire extinguisher on board also semi portable..what is a weight of CO2 cartridge  both in semi portable and also in 9 liter small one...what all different  semi portable fire extinguisher How hyper mist is work..how to test with false alarm.. What is freeing port, Bulwark , solid floor and types of solid floor Sewage discharge  condition with in 3 nautical mile and below 12 nautical miles What safety  are their on mechanical foam Objective of ISM, certificates  Definition of GRT, NRT dead weight, light weight, bulwark, intercostal/longitudinal girders (cross questions) etc  emergency fire pump regulations bitter end, bilge keel. Swash bulkhead location, purpose, construction Panting, pounding Collision  bulkhead Annex 1 , discharge criteria for oil Tanker Annex 1 machinery space discharge criteria IG system diagram, wet deck seal diagram and working IG system regulations ODMCS working Deck seal , explain...

MEO Class 4

Safety:  Certificates issued by port state and flag state and who sings them  safety radio certificate  CO2 10 yearly checks  hypermist system and what's the tank capacity  safety equipment certificate  Fire main safety all Emergency fire pump Sewage discharge criteria with bod regulations Water ingress alarm system full related to chap 12  Trajectory certificates Fire man outfit explain If fire line bust what action u will take? IG system Deck seal Marpol annexes Annex 6 in brief  ISM ISPS  Security levels Garboard & bilge strake? Fire control plan location and contents Annex 5 regulations Garbage management plan Annex 6 pollutants regulations and certificates Solas chapters DOC Annex 4 regulation and discharge criteria Annex 6 nox and sox value for tier 2 and 3.  Components in annexe  6 What are components on board for distress signal Scrubber tower test before discharging cargo.  ...

MEO Class 4

Safety: LRIT. LRIT working & difference with respect to AIS  SMPEP Polar code (structure requirements) what kind of steel for hull in polar regions solas chapter 12 Web frames.. location & use Coffer plate Marpol  Discharge  Annexe 1 Permeability of engine room Block coefficient prismatic coefficient  What will b condition of OWS in a special area? Ans auto mode  Coffine plate  Co2 system 5yearly routine coz pressure test  how its done ? Hypetmist ? How it works ?  Safety management system   About ISM..and. it's certificates  SSP -KEY points Emg fire pump fire class divisions(A 60,A50) tier 3 in ECA What is ibc code What is stability? Transverse metacentre Metacentre Ism Doc, SMS What is free board surface How to calculate it Draw load line BDN ORB 1  Free board marking Life boat markings  Hypermist system   PV v/v and PV breaker Sewage discharge criteria and appl...

MEO Class 4

Safety: IG requirements  Collision bulkhead How much strength collision bulkhead will be able to sustain as per regulations CO2 system regulations new regulations for life jacket foam fixed fire fighting system= how much is expansion ratio for my ship for machinery  space + how much capacity of foam is required as per regulations to fill machinery  space. Trammel gauge  garboard strake .. coffin plate Watertight weather-tight  door how to differentiate Duct keel  Capacity plan Discharge criteria annex 1 Nox tier 3  Emergency  fire pump Annex 1 Rise of floor Delivered  power and thrust power Sheer,aspect ratio, A-60 bulkhead Nox tier3,  ODS,VOC Motor: working principle of centrifugal pump+why it cannot handle air npsh, npshr, npshr for emergency fire pump as per regulations boiler mountings  Advantages of Vit Fuel pump working and tests done on fuel pump  Scavenge fire and * questions  Surg...

MEO Class 4

Safety:  Gmdss, EPERB how to activate eperb manually & automatically  LSA code ism SMS  Marpol annexe with date  Solas chapter & apply to which ship  Emg. dg & emg. fire pp regulations  Pounding panting tender stiff ship  Arrangements for panting n pounding Bwm  what is chamber  solas regulations for life raft all Name all annexe and explain annexe 6 (everything) overhead crane safties Name all motions of crane length between perpendicular? at what length it cuts rudder stock IG safeties  draw Deck seal  CO2 release if you are in Port and the Captain orders you to do, what will you do, (No timer and all, fully manual) Scavenge box temperature rise Precautions for scavenge inspection after a scavenge fire STCW chapters  what are the requirements for working hours? Under what conditions you wouldn't hand over the watch.  CO2 FF discharge criteria Marpol Annex 6...

MEO Class 4

Safety: MARPOL total annexes and Name them in order. What is ORB1- what are the entries made? Lifeboat markings, why there is + and - retroreflective marking? Lifeboat safety  Centrifugal brake working.. purpose.. location? Limit switch purpose ..working.. location Shell expansion plan Solas chapter 6 and 7 Regulation for watertight bulkhead (if sliding type) Anexx 6 content Chapters in solas and applicable for which ships. Sewage holding tank discharge criteria BOD of effluent Certificates under ism code, the chapter containing ism code, objectives. IAPP and EIAPP difference.  Iscs something related to classification societies. chapter 12 details. Nox Tiers and applicable for whom. Motor: Which Engine? Make? Single failure in steering gear?  What are tie rods? How do u know tie rod is tightened? How to tighten? From where? Tightening Wich direction? Boiler make?Type?Wich type of boiler burner?From where primary n secondary air comes? Draw ...

MEO Class 4

Motor: Type of engine Specification, MC-C stands for Lubrication in Engine Crosshead Lubrication How will we know Starting Air valve is leaking During Manoeuvring  Engine Fails to Start On Air Reasons Bursting disc Explain LT & HT corrosion Framo system Why IG used For which cargo we need IG IG requirement as per Deadweight of the ship The indication of Demister Fouled in Scrubber? Reasons for Hyd. oil Contamination  Magnetic filter purpose Working of an Exhaust valve, how to ensure valve rotation,  scavenge fire and actions, reasons for scavenge fire  crankcase inspection of generator  air compressor safeties gear pump overhaul boiler safeties,  fusible plugs and what all places they are used, fusible plug in a boiler,  you are on watch black out occurs your course of action, as per regulation in how many seconds the standby generator must start,  broken stud removal techniques,...

MEO Class 4

Safety: Solas chapter 12 full Annex 6 full, mainly Voc part Dynamic stability, Gz curve Req for emg towing oil tanker shell exp plan Stealer plate FSS code full Swash bulkhead location, purpose Certificate Carried related to solas chapter 9 Motor: AE lo contamination all possible causes Purifier pairing disc, Lubrication, water transducer Water tube boiler entire construction, with nomenclature Fwg less vacuum reasons & effects, high salinity reasons ME unit overhaul, hydraulic jack All about Threads Turbocharger, purpose of diffuser, drawing Self and central priming arrangement of pumps Vacuum condenser safeties, why VC Copt, how water level maintained in VC types of gate valve if gate valve struck inside, what will happen ,what will be ur action Air starting valve TIMING diagram for single unit counter weights in crankshaft (in ME & AE - how it is fitted) types of fuel injection  bilge valve, diff between sdnr nd slv shaft earthing , what...